Bcell (CD19+) chimerism
Test Name
Bcell (CD19+) chimerism
Home Collection, Lab Visit
Test Code
B0061
Test Components/ Genes/ Parameters
NA
Sample Report
Click on Icon
Test Information
TAT DETAILS
Daily by 6:00 PM, Report 7 Days
PRE-TEST INSTRUCTIONS
NA
CLINICAL UTILITY
To monitor engraftment after allogeneic hematopoietic stem cell transplant (HCT). Donor chimerism is reported as % donor.
SPECIMEN STABILITY
Ship at 2-8°C, Do not freeze
METHODOLOGY
Fragment Analysis STR
STORAGE TEMPERATURE
NA
SPECIMEN TYPE
2 ml Heparin Blood
Frequently Asked Questions
Bcell (CD19+) chimerism
To monitor engraftment after allogeneic hematopoietic stem cell transplant (HCT). Donor chimerism is reported as % donor.
The test is recommended post transplant for monitoring of Transplant success in patients following allogenic bone marrow transplant.
Fragment Analysis STR
Donor chimerism is reported as % donor. In addition, the report includes graphs showing percent of donor chimerism for subsets over post-transplant sample collection points.